Product

Fieldpiece SDMN6 Dual-Port Manometer and Pressure Switch Tester

  • Home
  • Fieldpiece SDMN6 Dual-Port Manometer and Pressure Switch Tester

Fieldpiece SDMN6 Dual-Port Manometer and Pressure Switch Tester

In Stock
Free Shipping Every Order 30-Day Returns Instant Wholesale Pricing Secure Checkout
Category:Heating Diagnostics, HVAC Tools & Equipment Brand:Fieldpiece SKU:FRG-FP-SDMN6 Model:SDMN6 Pressure range:up to ±60 inWC Units:inWC, mmWC, mbar, psi

Dual-port manometer and furnace pressure-switch tester with an adjustable draft-simulation pump. Measures ±60 inWC, displays differential pressure and captures switch opening/closing readings. Manufacturer-listed package includes static-pressure probes, test leads, tubing and case.

Your Price
$235.37 List$362.10
Save $126.73 (35% OFF)
In Stock SKU: FRG-FP-SDMN6
Secure SSL Checkout
Free Shipping
30-Day Returns

Product Details

The Fieldpiece SDMN6 combines a dual-port manometer with an internal draft-simulation pump for furnace pressure-switch testing. Measure gas, static and differential pressure, then use the adjustable pump to check the negative pressure at which a pressure switch closes and opens.

The display shows P1 or P2 together with the P1–P2 differential. During switch testing, a red indicator shows switch closure, and auto-capture can hold the pressure reading when continuity changes. This gives technicians a direct way to compare switch behavior with the equipment manufacturer’s rating.

Key features and benefits

  • Check furnace gas pressure: positive and negative pressure measurement covers a range of ±60 inWC.
  • Investigate duct restrictions: static-pressure probes and differential readings support pressure-drop checks across ductwork and equipment.
  • Test the switch independently: vary the internal pump speed to simulate draft rather than relying solely on the inducer’s operating pressure.
  • Use familiar units: select inWC, mmWC, mbar or psi; hold readings and disable automatic shutoff when the test requires it.

Applications

For HVACR diagnosis of furnace pressure switches, gas-regulator pressures, blower-related static pressure and building pressure differences. The ±60 inWC figure is the manometer measurement range, not a claim that the internal pump produces that full range of vacuum. Pressure-switch acceptance limits come from the switch or furnace manufacturer.

Specifications

Brand / model Fieldpiece SDMN6
Pressure measurement range −60 to +60 inWC
Selectable units inWC, mmWC, mbar and psi
Fine-range accuracy ±0.02 inWC from 0.00 to ±2.00 inWC
Higher-range accuracy ±1.5% full scale from 2.00 to ±60.0 inWC
Static-pressure resolution 0.01 inWC
Pressure connections P1 and P2; separate PUMP connection
Switch detection Continuity through test leads; closed-switch LED and auto-capture
Power 9 V alkaline battery
Battery life, manometer 200 hours typical, backlight off
Battery life, switch testing 12 hours at 27% pump speed, backlight off, approximately −2.5 inWC induced pressure without pump-bleed accessory
Automatic shutoff 15 minutes of inactivity; can be disabled
Compatible media Dry, non-corrosive gases
Operating environment 32–118°F / 0–48°C; below 80% RH

Package contents

  • SDMN6 dual-port manometer and pressure-switch tester
  • ANC1 four-pocket carrying case
  • ASP2s static-pressure probes
  • RMA316 pressure tubes
  • Quick-connect leads
  • Hoses and Y-splitter
  • Hoses with brass screw fittings

Manufacturer-listed SDMN6 package. No additional quantity of probes or tubing is implied beyond Fieldpiece’s listed contents.

Compatibility and use

For trained service professionals. Use only with dry, non-corrosive gases and keep moisture out of the hoses and instrument. Follow the manual’s instruction to turn off furnace power before pressure-switch testing. The 900 inWC / 17.4 psi sensor-damage warning is not an operating or measurement rating.

Application photos may show equipment sold separately. Refer to the package contents listed above.

Frequently Asked Questions

How much does shipping cost?
Nothing. Every order ships free via standard ground freight to addresses in the contiguous United States, with no minimum order value. Orders placed before 2:00 PM EST on a business day are typically dispatched the same day, and you receive a tracking email once your order ships. See our Shipping Policy for delivery windows and details.
What is your return policy?
You can return eligible items within 30 days of delivery in their original, unused condition. If your package arrives damaged, contact us for a full refund under the Frigentra Arrival Guarantee. This is separate from ordinary change-of-mind returns, and handoff to the carrier does not remove the guarantee. Packaging damage and cosmetic damage present on arrival are covered, including damage discovered after signing for delivery. Photos are optional, and the former 48-hour notification cutoff does not apply to arrival-damage refunds. Damage caused after delivery is not covered by the Arrival Guarantee. If we ship the wrong product, contact us and we will arrange a replacement or refund. Full details are in our Terms & Conditions (Returns and Refunds) and FAQ.
What payment methods do you accept?
We accept major credit and debit cards and the other payment methods shown at checkout. All payments are processed over a secure SSL connection.
How can I contact customer support?
Our team is available Monday to Friday, 8:00 AM to 6:00 PM EST at support@frigentra.com or +1 (863) 343-2288. You can also reach us through our contact page.

Related Products

Why Choose Frigentra

Buy With Confidence

Free shipping on every order, 30-day returns and instant wholesale pricing, backed by a knowledgeable support team.